Genomics/Microarray Facility
Services (DNA Sequencing)
Contact: Ms. Meifang Xie
Tel (215) 898-3991
Fax (215) 898-4521
MeiFang Xie has been running the sequencing facility
since 1995. The facility uses a ABI 3100 capillary machine for Sanger-type
sequencing with fluorescently-labeled dye-terminators, the ABI four-color
detection, and sequence analysis system. The ABI 3100 is a 16 capillary
machine that can sequence 600-650 clean basepairs for over 100 sequences
in a 24 hour period. The 3100 can also be configured for fluorescent
fragment detection and microsatellite analysis and is equipped with
Gene Scanning Software.
How
to use the facility
Click
here for the DNA Sequencing Submission Form
Purified DNA is provided by the investigator with an order
form specifying the quantity, form (double-stranded, single-stranded,
or PCR product) and size of the DNA. Ms.Meifang Xie is experienced
with sequencing PCR products and can assist in the estimation of
PCR product DNA quantity from ethidium-bromide-stained gel pictures
if necessary. It is essential that the size and concentration of
PCR products are determined accurately prior to sequencing. Lambda
or Bac clones require submission of greater quantities of DNA. Click
here for pricing information.
Procedures
For each sequencing run, investigators must provide, in numbered,
1.5 ml Eppendorf tubes.:
- (A) double-stranded
DNA:
1-1.5 µg of purified DNA at 0.2- 0.25 µg/µl
- (B) single-stranded
DNA
: 1 µg of purified DNA at 0.1- 0.125 µg/µl
- (C) PCR
products: at least 15ng of purified
DNA per 100 bp of PCR product in 5ul water.
- (D) Lambda
phage or Bac clones:
10ug purified DNA at 2-2.5 µg/µl
A name designation of 8 or fewer characters, and
the primers to be used for each run must be clearly indicated on
the submission form.
- M13 forward, M13 reverse, T7, T3, and SP6
primers are provided by the facility at no additional cost.
Specific primers must be supplied by the investigator at 3.2 pmoles/µl.
- Depending on well availability, DNA samples
delivered by 10:00 am will be available the next day at
3:00 pm. DNA samples for which the dye-terminator reactions have
been run by investigator can be delivered before 2:00 pm
for pick up the following day at 2:00 pm. No sequencing reactions
are run on Fridays.
What
to expect from the facility
-
For clean double-stranded templates, extremely
accurate sequence reads of 600-700 bases are obtained routinely.
-
sequence traces are
edited and text-files of sequence data are e-mailed
- the original result folder from the ABI basecaller
is placed in a computer folder for electronic retrieval if needed.
- other modes of delivery can be arranged.
Special Considerations*
*outside users must provide a PO# with
submission form or establish a Wistar account before sending samples.
***A rate of $5 per lane is charged for Wistar
staff wishing to run their own dye terminator or dye primer reactions
and have the facility sequence the DNA. Samples must be delivered
as dried precipitates and will be resuspended with formamide:EDTA
prior to loading, free of charge.
|